Mespere LifeSciences OEM Solutions

Mespere LifeSciences has successfully developed a number of breakthrough products in the field of cardiac and cerebral hemodynamic monitoring such as, the world's first non-invasive and continuous central venous pressure (VENUS 2000 CVP), jugular venous oximetry (VO 100), beat-by-beat Fick's Principle calculation for cardiac output, stroke volume, and volume preload/jugular vein distension (VenArt Dual Pulse Oximetry), and cerebral oximetry with blood volume (NeurOs Cerebral Oximetry) monitoring systems.

NeurOs Cerebral Oximetry

VENUS 2000 CVP

VO 100 Jugular Venous Oximetry

VenArt Dual Pulse Oximetry

Product Highlights

Modularized Sensors

All of Mespere LifeSciences sensors are modularized providing the best signal to noise ratio and allowing plug-and-play connectivity to external monitors

Wide Compatibility

With the option of integrated isolation Mespere LifeSciences sensors can be connected to either IEC 60601 (patient monitor) or IEC 60950 (PC) monitors

Accurate and Easy Measurements

Mespere LifeSciences sensors are all completely non-invasive and have been validated against the tradtional invasive methods proving that they are clinical sufficient substitutes. Now readings can be achieved in a matter of seconds versus minutes.

Specifications

NEUROS CEREBRAL OXIMETRY

StO2 Measurement Range:

Trending Accuracy of StO2:

Resolution of StO2:

Display Update Rate:

 

VENUS 2000 CVP

CVP Measurement Range:

Accuracy:

Resolution:

Sensitivity:

Display Update Rate:

 

VO 100 JUGULAR VENOUS OXIMETRY

SjvO2 Measurement Range:

Accuracy of SjvO2:

Resolution of StO2:

Display Update Rate:

 

ELECTRICAL

Power Draw:

Voltage Input:

Measurement in NIR Wavelength:

NIR Power:

 

I/O Signals:

 

ENVIRONMENTAL

Temperature:

 

Humidity:

 

Air Pressure:

 

 

COMPLIANCE

Safety Standard for Medical Equipment:

EMC Standard:

Degree of Protection:

Mode of Operation:

DB 9-PIN CONNECTOR

NEUROS CEREBRAL OXIMETRY

A0 - 100%

A±1.5%

A1%

A1 second

VENUS 2000 CVP

A0 - 20 mmHg or 0 - 27 cmH2O

A±2.16 mmHg or ±2.94 cmH2O
A±1 mmHg or ±1 cmH2O

A±1 mmHg or ±1 cmH2O

A1 second

VO 100 JUGULAR VENOUS OXIMETRY

A0 - 100%

A± 2.7%

A1%

A1 second

ELECTRICAL

A200 mW typical operation @ 5.0VDC input voltage

A+5.0VDC ± 0.25VDC, w/50mV max. ripple

A905±5nm, 740±4nm, and 660±3nm

APeak: 14 mW

AAverage: 0.9 mW

A0 to +5.0VDC (nominal) @ +5.0VDC input voltage

ENVIRONMENTAL

AOperating: 10 - 38 degrees Celsius

ATransportation/Storage: -20 - 50 degrees Celsius

AOperating: 30 - 70 %

ATransportation/Storage: 20 - 80%

AOperating: 86 - 106 kPa

ATransportation/Storage: 86 - 106 kPa

A

COMPLIANCE

AIEC 60601-1 edition 3 Amendment 1

AIEC 60601-1-2 Class A

AType BF-Applied Part

AContinuous

Contact Us

 Address: 180 Frobisher Drive, Waterloo, ON, Canada, N2V 2A2

© 2023 by Mespere LifeSciences. 

Tel: 519-884-7575